Please login or register in order to view and post in the Forum.
Hi Chad,
Is 31 the maximum allowable reversal size for P&F charts in IRT? If I try to enter anything higher then 31, reversal size automatically flips to 3.
Are you able to reproduce this issue?
Yes, the limit of the PNF periodicity is 31 for the reversal. You could consider doubling the box size.
If you use the layered PNF periodicity as seen below, there is no such limitation.
Thank you, Chad. Just wanted to make sure this works as expected and is not a bug. I'll figure something out based on your recommendations.
Hi Chad,
Are you able to reproduce this issue?
Yes, the limit of the PNF periodicity is 31 for the reversal. You could consider doubling the box size.
If you use the layered PNF periodicity as seen below, there is no such limitation.
Thank you, Chad. Just wanted to make sure this works as expected and is not a bug. I'll figure something out based on your recommendations.